Product Image
These duplex test leads are fitted with hook terminations for connecting to an instrument and a Connex plug.
Test connection terminations are supplied separately.
The duplex connector incorporates a locking ring to prevent test connections being pulled off in use.
Duplex connect test lead system for use with any Megger 10 A DLRO and BT51 instruments
The Megger DLRO duplex connect four terminal test lead system is designed to provide the most cost effective and convenient way to provide the user with all of the test lead terminations and lead lengths required for the many different applications encountered in low resistance testing.
At the center of this unique test lead system is a bespoke connector allowing terminations such as kelvin clips or duplex test probes to be changed as required. There are two connector versions, one being fitted with indicator LEDs that operate with the DLRO10 range of instruments. The indicator LEDs provide enhanced safety and convenience with indications as follows:
All of these important indications are therefore seen near the point of connection without needing to view the instrument display. There is even a 6 m extension lead to provide the ultimate in flexibility.
If it is impossible to de-energize the circuit, (e.g. high voltage batteries cannot be switched off while their connections are tested) the user must be aware of the dangers. The instrument terminals will become live when connected to the circuit. Therefore when used on hazardous voltages the Megger terminal cover (available separately) must be used. See the accessories section of this user guide.
When running any test, or when attached to a test load, do not undo the modular connections. Isolate both test leads before changing any part of the modular leadset.
These test leads on their own not safety CAT rated due to the bare hook terminations. However when fitted with insulating instrument terminal covers and a suitably rated test termination the overall safety CAT rating will be the lowest of the ratings between the instrument, the terminal covers and the test termination.
For example if used with a DLRO10HD fitted with terminal cover part number 1002-390 and a pair of DP1-C duplex probes the safety rating of the complete system will be CAT III 300 V. However if the test terminations were changed to KC1-C Kelvin clips the safety rating would drop to <30 V as the KC1-C are unrated.
This product is not intrinsically safe. Do not use in an explosive atmosphere.
Do not operate the test leads or connect to any external system if any visible signs of damage are apparent or if they have been stored for prolonged periods in unfavorable conditions.
Before each use of the test leads, perform a thorough visual inspection to confirm that their condition is good, with no damaged or broken insulation.
The Measurement Category rating of the measurement system is that of the lowest rated component. If any part of the measurement leads is unrated, the instrument is safe for connection only up to 30 V.
The Megger TL1.5-C Test Lead 1.5 m Connect (X1) # 1006-452 is manufactured by Megger. Valley Instrument Service is an authorized Megger dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681Accessories, replacement sensors, and parts for this product family.
| Model | Price | |
|---|---|---|
1006-452Current | Request Quote | Viewing |
1006-453 | Request Quote | View Details → |
1006-454 | Request Quote | View Details → |
1006-455 | Request Quote | View Details → |

1 kV Control Lead Set 15 kV Plug 2 x 3 m

1 kV Fused Lead Set 15 kV Plug 2 x 1.25 m

Megger 1 kV fused HV test lead set with interchangeable needle probes and mini hook-clips, for the low-voltage control-circuit test mode of the Advanced and Expert 5/10 kV insulation testers — MIT525/2 (1016-086), MIT1025/2 (1016-096), S1-568/2 (1016-106), and S1-1068/2 (1016-112). In-line fuse protects the instrument when the probe accidentally lands on a live circuit.

15 kV Lead Set 15 kV Plug 3X10 m, 15 kV Clip