FLUKE-1760 BASIC | The Fluke 1760 three-phase energy logger provides undisputable verification in a Class-A compliant package designed for advanced power quality analysis. | Fluke 1760 records rms values together with corresponding minimum and maximum values for:• Voltage• Current• Power P, Q, S• Power Factor• kWh• Flicker• Unbalance• Frequency• Harmonics/Interharmonics continuously with the following time aggregations: Day, 10 min, Free Interval, e.g.: 15 min, 2 h | Aggregation time is adjustable between 10 ms (1/2 cycle), 20 ms (1 cycle), 200 ms (10/12 cycles) or 3 sec (150/180 cycles). | Overload conditionUnder load condition | appr. 4.9 kg; 10.8 lbs (without accessories) | Request Quote | View Details → |
FLUKE-1760 US | The Fluke 1760 three-phase energy logger provides undisputable verification in a Class-A compliant package designed for advanced power quality analysis. | Fluke 1760 records rms values together with corresponding minimum and maximum values for:• Voltage• Current• Power P, Q, S• Power Factor• kWh• Flicker• Unbalance• Frequency• Harmonics/Interharmonics continuously with the following time aggregations: Day, 10 min, Free Interval, e.g.: 15 min, 2 h | Aggregation time is adjustable between 10 ms (1/2 cycle), 20 ms (1 cycle), 200 ms (10/12 cycles) or 3 sec (150/180 cycles). | Overload conditionUnder load condition | appr. 4.9 kg; 10.8 lbs (without accessories) | Request Quote | View Details → |
FLUKE-1760 TR US | The Fluke 1760 three-phase energy logger provides undisputable verification in a Class-A compliant package designed for advanced power quality analysis. | Fluke 1760 records rms values together with corresponding minimum and maximum values for:• Voltage• Current• Power P, Q, S• Power Factor• kWh• Flicker• Unbalance• Frequency• Harmonics/Interharmonics continuously with the following time aggregations: Day, 10 min, Free Interval, e.g.: 15 min, 2 h | Aggregation time is adjustable between 10 ms (1/2 cycle), 20 ms (1 cycle), 200 ms (10/12 cycles) or 3 sec (150/180 cycles). | Overload conditionUnder load condition | appr. 4.9 kg; 10.8 lbs (without accessories) | Request Quote | View Details → |
FLUKE-1760TR BASIC | Power Quality Monitor – Fluke’s three-phase power quality recorder is fully compliant to IEC 61000-4-30 Class-A and is consistent with compliance testing. | Fluke 1760 records rms values together with corresponding minimum and maximum values for:• Voltage• Current• Power P, Q, S• Power Factor• kWh• Flicker• Unbalance• Frequency• Harmonics/Interharmonics continuously with the following time aggregations: Day, 10 min, Free Interval, e.g.: 15 min, 2 h< | Aggregation time is adjustable between 10 ms (1/2 cycle), 20 ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles). | overload conditionunder load condition | appr. 4.9 kg; 10.8 lbs. (without accessories) | Request Quote | View Details → |