Multi-spot temperature sensor for ambient-temperature tank gauging — measures liquid temperature at multiple heights with up to 16 Pt-100 spot elements. Hung vertically from the top of the tank, length specified per tank height (2-70 meters / 80-2700 inches). 1-in 316 SST sheath, ANSI or EN flanged tank connections, four-wire / three-wire RTD options. IEC 60751 Class 1/6 B-sp tolerance (Class 1/10 also available with four-wire). Designed for atmospheric tanks up to 0.2 bar (2.9 psi); pressurized tanks require a thermowell. Pairs with the Rosemount 2240S Multi-Input Temperature Transmitter for FOUNDATION Fieldbus / Tankbus output.
The tank-spanning length of the sensor. Metric range 2000-70000 mm (2-70 m) in 10 mm steps. US range 80-2700 in (≈6.7-225 ft) in 1 in steps. Custom length specified at quote.
ANSI raised-face flanges (A-L), EN flat-face flanges (1-7), or M33×1.5 threaded (code 0). All flanges in SST AISI 316.
1-16 spot elements distributed along the sensor length. Tank-gauging applications typically use 6-16 elements for full vertical profile.
IEC 60751 spec. Class 1/10 (code 2) requires four-wire sensor wiring.
Standard integrated installation with Rosemount 2240S transmitter is code 00. Specify a length code for remote-mount installations: 04-10 in meters, 13-33 in feet.
Rosemount is configurator-heavy and quote-only — Valley Instrument verifies option compatibility, lead time, and pricing before confirming your order.