SKU: FLUKE-NORMA 6004
Portable wideband precision power analyzer for field environments. Battery-powered (10 hours), 0.1% measurement accuracy and 500 kHz bandwidth. Available in 3-channel (6003) and 4-channel (6004) configurations.
List price. Volume pricing available.
Fluke Norma Power Analyzers deliver precision measurements of 1 or 3 phase current and voltage, harmonics analysis, and Fast Fourier Transformation analysis.
The Fluke Norma 6004 Portable Power Analyzer (4-Channel, Battery-Powered, Field-Use) # FLUKE-NORMA 6004 is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| General | General Specifications |
| Number of Phases | 1 to 3 |
| Weight | Approx. 5 kg (11 lb) |
| Size | 5.9 x 9.3 x 12.4 in |
| On-board Printer | No |
| Display | User-selectable background lighting and contrast. |
| Bandwidth | DC to 3 MHz or DC to 10 MHz depending on input module |
| Basic Accuracy | 0.2%, 0.1% or 0.03% depending on input modules |
| Sampling Rate | 0.33 MHz or 1 MHz depending on input modules |
| Voltage Input Range | 0.3 V to 1000 V |
| Current Input Range (direct, not via shunt) | 0.03 mA to 20 A depending on input module |
| Memory for Configurations | 4 MB |
| Memory for Settings | 0.5 MB |
| Fast Fourier Transformation (FFT) | To the 40th harmonic |
| RS232/USB Interface | Standard |
| PI1 Process interface (8 analog/impulse inputs and 4 analog outputs) | Optional |
| IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s) | Optional |
| Fluke NormaView PC software (for data download, analysis and report writing) | Standard |
| Digital Oscilloscope (DSO) | Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion. |
| Integration function (energy) | Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available. |
| Vector Display | Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal. |
| Recorder | Display of average values over time for trend determination. |
| RAM data memory | From the RAM approximately 4 MB are available for the storage of measured values. |
| Configuration | Set up the analyzer to measure and display data in the format required. |
| Working Temperature Range | 5°C to 35°C (41°F to 95°F) |
| Storage Temperature Range | -20°C to 50°C (-4°F to 122°F) |
| Housing Material | Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements. |
| Climatic Class | KYG DIN 40040, max. 85% relative humidity, non-condensing. |
| Power supply | 85 V AC to 264 V AC, 50 Hz to 60 Hz, DC 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models. |
| Measuring Inputs | Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket. |
| Operation | Membrane keyboard with cursor – function keys and direct functions. |
| Connections | Rear panel of the 3-phase Analyzer |
| Range | DC and 0.2 Hz to sample rate |
| Accuracy | ±0.01% of measured value (reading) |
| Options | Ethernet / 10 MBit/s or 100 Mbit/s |
| Electrical Safety | Degree of pollution 2, safety Class I |
| Maximum inputs | For current inputs Measurement range 10 Aeff, 20 Apeak |
| Net input | case (protective conductor): 1.5 KV AC |
| Net connection | Measurement input: 5.4 kV AC |
| Measurement inputs | Case: 3.3 kV AC |
| Measurement input | input: 5.4 kV |
| Emission | IEC 61326-1, EN 50081-1, EN 55011 Class B |
| Immunity | IEC 61326-1 / Annex A (industrial sector), EN 50082-1 |
| Electromagnetic susceptibility | Power Phase Channels |
| Current range | 20 A |
| Sampling rate | 341 kHz |
| Nominal current (calibration point) | 32 A |
| Basic accuracy at calibration point [%] | ± 0.03 |
| Basic accuracy at nominal current [%] | ± 0.03 |
| Nominal voltage drop [V] | 320 mV |
| Nominal resistance [Ohm] | 10 mΩ |
| Short time overrange(5s load 15s interval) | 100A/ 1s-5s |
| Overload Wmax | - |
| Frequency range | - |
| Angular accuracy [°/kHz] | ± 0.1 |
| Frequency influence [%/kHz] | - |
| Load influence [%/A2] | - |
| Temperature coefficient [ppm/K] | ≤10 |
| Weight (kg / lbs) | 0.62 /1.36 |
This product is part of a family with 2 models. Select a model below to view details.
| Model | Price | |
|---|---|---|
FLUKE-NORMA 6003 | Request Quote | View Details → |
FLUKE-NORMA 6004Current | Request Quote | Viewing |

Aux Input Cable

Three-phase power measurement logger for energy studies and load profiling. Versatile, portable, and Fluke Connect compatible.

Upgrade Kit for 1736 to 1738, Eur/US Only

Three-phase power quality logger for energy and power studies. Capture voltage, current, power, and harmonics with iFlex flexible current probes. Fluke Connect compatible.