SKU: FLUKE-1775/BASIC
At-a-glance power quality health for faster troubleshooting. Capture high-speed transients up to 8 kV. View V/A/Hz, power, dips, swells, and harmonics data.
List price. Volume pricing available.
At-a-glance power quality health for faster troubleshooting. Capture high-speed transients up to 8 kV. Easily view V/A/Hz, power, dips, swells, and harmonics data.
The Fluke 1775 Three-Phase Power Quality Analyzer, Basic # FLUKE-1775/BASIC is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Number of inputs | 4 inputs, 3 phases and neutral referenced to PE (5 connectors) |
| Measurement category | 1000 V CAT III / 600 V CAT IV |
| Maximum input voltage | 1000 V rms / 1000 V dc (1700 Vpk) |
| Nominal voltage range | Wye and single phase: variable (50 V – 1000 V)Delta: Variable (100 V – 1000 V)IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 V |
| Input impedance | 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE |
| Bandwidth | DC to 30 kHz for PQ measurements, excluding transients |
| Resolution | 24-bit synchronous sampling |
| Sampling frequency | 80 kS/s at 50/60 Hz |
| Scaling | 1:1, variable for use of potential transformers |
| Measurement range | ±8 kV |
| Sampling rate | 1775: 1 MS/s1777: 1 MS/s, 20 MS/s |
| Trigger | Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz |
| AC | 1 A to 1500 A with i17XX-FLEX1500 121 A to 1500 A with i17XX-FLEX1500 181 A to 1500 A with i17XX-FLEX1500 243 A to 3000 A with i17XX-FLEX3000 246 A to 6000 A with i17XX-FLEX6000 3640 mA to 40 A with clamp i40s-EL4 A to 400 A with clamp i400s-EL |
| DC | 20 A to 2000 A with 80i-2010-EL clamp |
| Input voltage | Clamp: 50 mV / 500 mV rms; CF 2.8Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4all at nominal probe range |
| Range | Wired connection with 17XX-AUX adapter |
| Input range | Direct: 0 V dc to ± 10 V dc0 V to 1000 V dc |
| Scale factor | Format: mx + b (gain and offset) user configurable |
| Displayed units | User configurable (up to 8 characters, for example °C, psi, or m/s) |
| Input mains frequency | DC, 50/60 Hz 15 % (42.5 Hz … 57.5 Hz, 51 Hz … 69 Hz) |
| Topologies | 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta |
| Data storage | Fluke 1773/1775: 8 GB internal (expandable with microSD card)Fluke 1777: 32 GB microSD card (installed) |
| Memory size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.The number of possible logging sessions and logging period depends on user requirements |
| Real time accuracy | Internal: 3 ppm (0.26 s per day, 8 s per month)NTP (internet time): Depending on internet latency, typical GPS: < 1 ms absolute to UTC |
| Measured parameter | See operator manual |
| Trend interval | User selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
| Averaging interval min/max values | Voltage, Current: ½ cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)Aux, Power: 200 ms |
| Total harmonic distortion | THD for voltage and current is calculated on 50 harmonics |
| Harmonics | h0 … h50% fund and RMS for voltage, current and powerPhase angles for voltage and current up to h11 |
| Interharmonics | ih0… ih50% fund and RMS for voltage and current |
| Supraharmonics | 2–9 kHz with 200 Hz bins9–30 khz with 2 kHz binsRMS for voltage and current |
| Harmonics measurement method | Grouped, sub-grouped and single harmonic bins according to IEC 61000-4-7.Method selected automatically based on configured PQ standard or user configurable. |
| Mains signaling | 2 frequencies in the range from 110 Hz to 3000 Hz |
| Voltage | Dip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients |
| Current | Inrush current |
| Triggered recordings | Half cycle RMS of voltage and current for 10 sWaveform of voltage and current for 10/12 cyclesMains signaling: 200 ms RMS of mains signaling voltage up to 120 sTransients: Waveform of voltage(Fluke 1777: 1 MS/s or 20 MS/s, 500,000 pts, Fluke 1775: 1 MS/s, 25,000 pts) |
| Power | IEEE 1459 |
| Flicker | IEC 61000-4-15 Class F1 |
| Power quality | IEC 61000-4-30 Class A, IEC 62586 PQI-A-PI |
| Power quality compliance | EN 50160 + GOST + NEQUAL + NETCODE + FOL |
| Ethernet | 1 Gbit/s 1000BASE-T |
| USB type A | USB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA |
| USB-C | USB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA |
| WiFi/BLE module1 | 802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client modeBluetooth 5.0/BLEAntenna: Internal and external2 |
| LTE/4G module3 | LTE-A Cat 12Worldwide LTE-A and UMTS/HSPA+ coverageAntenna: External2 |
| GPS | MCX connector to attach a GNSS antenna for GPS/GLONASS2 |
| Events | 1 Not in 177X/BASIC versions2 Requires 5m extension cable, Fluke p/n 52639153 Availability and supported providers vary by country. Check with your local Fluke representative. |
| Voltage dips and swells | - |
| Voltage transients | ±8 kVpk |
| Voltage harmonics/interharmonics | 100 % |
| THD on voltage | 100 % |
| Voltage distortions 2-9 kHz | Max 100 V |
| Voltage distortions 9-30 kHz | Max 100 V |
| With iFlex 1500 A,i17XX-FLEX1500 18 | 150 A1500 A |
| With iFlex 3000 A,i17XX-FLEX3000 24 | 300 A3000 A |
| With iFlex 6000 A,i17XX-FLEX6000 36 | 600 A6000 A |
| With AC clamp 40 A,i40s-EL | 4 A40 A |
| With AC clamp 400 A,i400s-EL | 40 A400 A |
| With AC/DC clamp2000 A, 80i-2010s-EL | 200 A2000 A |
| Current min/max | 100 % |
| Current harmonics/interharmonics | 100 % |
| THD on current | 100 % |
| Frequency | 42.5 Hz … 69 Hz |
| Voltage unbalance | 100 % |
| Current unbalance | 100 % |
| Flicker Pinst, Pst, Plt | 0 to 20 |
| Mains signaling voltage | Up to 3 kHz0-15 % of Vnom |
| AUX input | ±10 V |
| Clamp: 50 mV / 500 mVRogowski: 15 mV / 150 mV | 4 A / 40 A |
| Clamp: 50 W / 500 WRogowski: 15 W / 150 W | 4k W / 40 kW |
| Max. resolution W, VA, var | 0.1 W |
| Phase (voltage to current)1 | ±0.2° |
| 150 A / 1500 A | 300 A / 3000 A |
| 150 kW / 1.5 MW | 300 kW / 3 MW |
| PF ≥ 0.99 | 150 A / 1500 A |
| 1.2 % + 0.005 % | 1.2 % + 0.0075 % |
| Active energy Ea | 0.1 ≤ PF < 0.99 |
| Apparent power SApparent energy Eap | 0 ≤ PF ≤ 1 |
| Reactive power QReactive energy Er | 0 ≤ PF ≤ 1 |
| Additional uncertainty(% of power high range) | VP-N > 250 V |
| Phase (voltage to current) | - |
| Warranty | Analyzer: 2 years (battery not included)Accessories: 1 year (including battery) |
| Calibration cycle | 2 years |
| Size (L X W X HD) | 28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in) |
| Weight | 2.1 kg (4.6 lb) |
| Anti-theft protection | Slot to support Kensington lock |
| Operating temperature range | -10 °C to 50 °C |
| Storage temperature range | -20 °C to 60 °C |
| Operating humidity | IEC 60721-3-3: 3K5, modified:-10 °C to 30 °C: ≤95 %, no condensation or ice35 °C: 70 %40 °C: 55 %50 °C: 35 % |
| IP Rating | IEC 60529: IP50 |
| Vibration | IEC 60721-3-3 / 3M2 |
| Voltage range | 100 V – 600 V -15 % / +10 % (85 V … 660 V) |
| Power consumption | Max. 40 VA |
| Mains frequency | 50/60 Hz (42.5 Hz … 69 Hz) |
| UPS | Li-Ion battery BP1770 with extended temperature range, customer replaceableOn-battery runtime: 1.5 hours |
| General | IEC 61010-1: Pollution Degree 2 |
| Power supply | Overvoltage Category IV 600 VWith Mains Adapter MA-C8: Overvoltage Category II 300 V |
| Measurement | IEC 61010-2-030: CAT IV 600 V, CAT III 1000 V |
| Altitudes 2000 m to 4000 m | Derate to:Power Supply: Category IV 300 VWith MA-C8 Adapter: Category II 150 VMeasurement: CAT IV 300 V, CAT III 600 V, CAT II 1000 V |
This product is part of a family with 6 models. Select a model below to view details.
| Model | Price | |
|---|---|---|
FLUKE-1773/BASIC | Request Quote | View Details → |
FLUKE-1773 | Request Quote | View Details → |
FLUKE-1775/BASICCurrent | Request Quote | Viewing |
FLUKE-1775 | Request Quote | View Details → |
FLUKE-1777/BASIC | Request Quote | View Details → |
FLUKE-1777 | Request Quote | View Details → |

Aux Input Cable

Three-phase power measurement logger for energy studies and load profiling. Versatile, portable, and Fluke Connect compatible.

Upgrade Kit for 1736 to 1738, Eur/US Only

Three-phase power quality logger for energy and power studies. Capture voltage, current, power, and harmonics with iFlex flexible current probes. Fluke Connect compatible.