DSX CableAnalyzer Series Copper Cable Certifiers
The Fluke 2 GHz DSX Multimode OLTS Inspc V2, with Wi-Fi # DSX2-8000MI is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Shielded and unshielded pair LAN cabling | TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω |
| Permanent link adapters | Plug type: shielded RJ45 Optional Plug type: Tera |
| Channel Adapters | Jack type: shielded RJ45 Optional Jack type: Tera, GG45 |
| TIA | Category 3, 4, 5, 5e, 6, 6A, 8 per ANSI/TIA-568.2-D |
| ISO/IEC | Class C and D, E, EA, F, FA and I/II certification per ISO/IEC |
| Maximum frequency | DSX-8000: 2000 MHz; DSX-5000: 1000 MHz |
| Speed of Autotest | DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA: 8 seconds. Full 2-way Autotest of Category 8: 16 seconds DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds |
| Input protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
| Display | 5.7 in LCD display with a projected capacitance touchscreen |
| Case | High impact plastic with shock absorbing overmold |
| Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
| Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
| Main unit and remote: | Lithium ion battery pack, 7.2 V |
| Typical battery life: | 8 hours |
| Charge time* | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity. |
| Languages supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian |
| Calibration | Service center calibration period is 1 year |
| Integrated Wi-Fi | Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
| Operating Temperature | 32°F to 113°F (0°C to 45°C) |
| Storage Temperature | -14°F to +140°F (-10°C to +60°C) |
| Operating relative humidity | 0 % to 90 %, 32°F to 95 °F (0°C to 35°C) 0 % to 70 %, 95°F to 113 °F (35°C to 45°C) |
| Vibration | Random, 2 g, 5 Hz-500 Hz |
| Shock | 1 m drop test with and without module and adapter |
| Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
| Operating altitude | 13,123 ft (4,000 m) 10,500 ft (3,200 m) with ac adapter |
| EMC | EN 61326-1 |
| DSX-8000 | Category 8 test modes (or lower link categories) Class I/II test modes |
| DSX-5000 | Category 6A/Class EA test modes (or lower link categories) Class FA test modes |
| Length of Twisted Pair Cabling1 | Without Remote or in DSX-5000 Long Communication Mode |
| Range | 800 m (2600 ft) |
| Resolution | 0.1 m or 1 ft |
| Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
| Propagation Delay | Without Remote or in DSX-5000 Long Communication Mode |
| Range | 4000 ns |
| Resolution | 1 ns |
| Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns |
| Range | 0 ns to 100 ns |
| Accuracy | ± 10 ns |
| Range | 0 Ω to 540 Ω |
| Resolution | 0.1 Ω |
| Accuracy | ± (1 Ω + 1 %) |
| Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |

087724767001 TS30/120 Angl/Pin

1 GHz DSX Cable Analyzer Modules Add on Kit

Get the Fluke BT521 Advanced Battery Analyzer with intelligent test probe set. The 500 series battery impedance tester can analyze stationary lithium ion batteries and battery banks internal battery resistance.