SKU: 8800R
Reducer-body vortex variant of the Rosemount 8800 — the meter integrates concentric reducers on each end to accurately measure flow rates BELOW the standard turn-down range while maintaining the same face-to-face dimensions as the larger flanged 8800. Ideal for retrofitting an existing larger-line installation that's now running below the standard meter's turndown threshold (low-flow steam, low-flow gas, off-design operation). Same gasket-free, all-welded body and same multivariable mass-flow capability as the 8800 Flanged.
Contact us for pricing on this product.
Reducer-body vortex variant of the Rosemount 8800 — the meter integrates concentric reducers on each end to accurately measure flow rates BELOW the standard turn-down range while maintaining the same face-to-face dimensions as the larger flanged 8800. Ideal for retrofitting an existing larger-line installation that's now running below the standard meter's turndown threshold (low-flow steam, low-flow gas, off-design operation). Same gasket-free, all-welded body and same multivariable mass-flow capability as the 8800 Flanged.
The Rosemount 8800 Reducer Vortex Flow Meter # 8800R is manufactured by Rosemount. Valley Instrument Service is an authorized Rosemount dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681Reducer-style vortex flow meter — built-in flow conditioner reducer expands measurement range downward by 30-50%, enabling accurate low-flow measurement on lines that would otherwise be over-sized. Same all-welded sensor + isolated-design platform as the 8800-FLANGED. Used when a single line size needs both normal and turndown flow measurement. Configured via the Instrumart 8800D family configurator (shared with FLANGED + DUAL variants).
Rosemount is configurator-heavy and quote-only — Valley Instrument verifies option compatibility, lead time, and pricing before confirming your order.

Redundant-sensor vortex flow meter — two independent vortex sensors and electronics in one meter body provide functional safety integrity (SIL 2 / SIL 3) for Safety Instrumented System (SIS) applications. Each sensor is independently powered, signal-conditioned, and output-isolated. Used in burner-management systems, emergency shutdown trip loops, overpressure protection, and any SIS loop where a spurious trip or a missed trip carries safety / production / regulatory consequences. Same gasket-free 8800 platform, same multivariable mass-flow capability, doubled diagnostic confidence.

Gasket-free, all-welded vortex flow meter — eliminates the leak points that traditional gasketed vortex bodies suffer in steam, condensate, and high-temperature service. Isolated sensor design provides flow + temperature measurement in one device. Multivariable output (mass + volumetric + temperature). Wide line size range (½ to 12 in / DN15 to DN300). HART or FOUNDATION Fieldbus output. The vortex workhorse for steam, condensate, low-viscosity liquids, and gas service where DP / Coriolis would be over-spec.