

SKU: FLUKE-PVA-1500T2
Get the Fluke BT521 Advanced Battery Analyzer with intelligent test probe set. The 500 series battery impedance tester can analyze stationary lithium ion batteries and battery banks internal battery resistance.
List price. Volume pricing available.
Get the Fluke BT521 Advanced Battery Analyzer with intelligent test probe set. The 500 series battery impedance tester can analyze stationary lithium ion batteries and battery banks internal battery resistance.
The Fluke PVA-1500T2 Solmetric PV Analyzer IV Curve Tracer # FLUKE-PVA-1500T2 is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Voltage Range (Voc) | 20 to 1500V DC |
| General | Maximum Current Range (Isc) |
| Module Efficiency <19% | 0 to 30A DC |
| Module Efficiency ≥19% | 0 to 10A DC |
| Voltage Accuracy (0 °C to 45 °C) | ±(0.5% ±0.25V) |
| Current Accuracy (0 °C to 45 °C) | ±(0.5% ±0.04A) |
| Power Accuracy (0 °C to 45 °C) | ±(1.7 % + 1.0 W) (current ≥3 A, module efficiency <19 %) |
| Voltage Resolution | 25 mV |
| Current Resolution | 2 mA |
| Sweep-to-sweep delay (@VOC ≤ 1350V) | <9 seconds |
| Max number of I-V sweeps per hour (@VOC ≤ 1350V) | 400 sweeps/hr |
| Max megawatts measured per hour | 3.5 MW/hr |
| # sweeps at 18 s sweep-to-sweep delay | unlimited (25 °C, 77 °F ambient)550 (45 °C, 113 °F ambient) |
| # sweeps at 9s sweep-to-sweep delay | unlimited (25 °C, 77 °F ambient)330 (45 °C, 113 °F ambient) |
| I-V Trace Points | 100 or 500 (selectable) |
| I-V Sweep Duration | 0.05 to 2 seconds (typically 0.2 seconds for PV strings) |
| Operating Temperature Range | 0 °C to 45 °C, 32 °F to 113 °F |
| Storage Temperature Range | -20 °C to 65 °C, -4 °F to 149 °F |
| Operating Humidity | <90 % RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used. |
| Altitude | 2000 m max |
| Battery Charging Time | 6 hr |
| Battery Run Time | Approx. 8 hr |
| Safety and Regulatory | CAT III 1500VIEC 61010-1: Pollution Degree 2 |
| Warning Features | Over-voltage, over-current, over-temperature, reversepolarity |
| PV Connector | Staubli MC4-EVO2 |
| Charging/Charged LED | Yes |
| In-the-field firmware update-ready | Yes |
| Interface to Tablet/Laptop | Wi-Fi interface between user tablet or laptop, I-V unit andSolSensor |
| Weight | 6.6 kg, 14.55 lb |
| Height | 43.2 cm, 1.41 ft (including test lead and strain reliefs) |
| Width | 21.6 cm, 8.50 in |
| Depth | 15.2 cm, 5.98 in |
| Voltage Range | 0 to 1500V DC |
| Current Range | 0 to 30A DC |
| Temperature | 0 °C to 45 °C, 32 °F to 113 °F |
| Humidity | Maximum relative humidity of 80% for temperatures up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F) |
| Pollution Degree | 2 |
| Lead Length | 152 cm, 59.84 in |
| Lead Colors | Positive=red, negative=black |
| Manufacturer (Test Leads and Alligator Clips) | Staubli |
| Sensor Type | Silicon photodiode with corrections for temperature, spectral, and angular effects |
| Measurement Range | 100 W/m² to 1500 W/m² |
| Accuracy | ±2 % when used to predict the performance of well characterized poly- and monocrystalline PV modules with direct irradiance >600W/m² |
| Resolution | 1 W/m² |
| Measurement Interval | Typically, 3.5 s |
| Measurement Synchronization with I-V Curve | Typically, <1 s |
| Wireless Range (open line of sight) | 100 m, 328 ft |
| Key Features | TiS75+ |
| Infrared resolution | 384 x 288 (110,592 pixels) |
| IFOV | 1.91 mRad |
| Field of view | 42° x 30° |
| Minimum focus distance | 0.15 m |
| Focus system | Manual focus |
| Wireless connectivity | Yes, to PC, iPhone and iPad (iOS 4s and later), Android 4.3 and up, and WiFi and LAN (where available) |
| Fluke Connect app compatible | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
| Fluke Connect Assets optional software | Yes*, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location |
| Asset Tagging | Scan a QR code to automatically organize and file thermal images with Fluke Connect |
| IR-Fusion technology | AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image |
| Picture-InPicture (PIP) | Yes |
| Display | 3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
| Ergonomic design | Designed for one-handed use |
| Thermal sensitivity | 40mk |
| Level and span | Smooth auto and manual scaling |
| Fast auto-rescale in manual mode | Yes |
| Minimum span (in manual mode) | 3° °C (4.5 °F) |
| Minimum span (In auto mode) | 5°C (9.0 °F) |
| Built-in digital camera (visible light) | 640 x 480 |
| Frame rate | 9 Hz or 27 Hz models |
| Dew point calculation | Yes |
| Internal memory | ∼500 images |
| External memory | ≥4 GB SD card (>1000 images) |
| Image capture, review, save mechanism | One-handed image capture, review, and save capability |
| Image file formats | Non-radiometric BMP or JPEG or fully-radiometric is2 |
| Memory review | Yes |
| Software | Fluke Connect software—full analysis and reporting software with access to the Fluke Connect |
| Analyze and store radiometric data on a PC | Yes |
| Export file formats with Fluke Connect software | is2, BMP, GIF, JPEG, PNG, TIFF |
| Voice annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. |
| IR-PhotoNotes | Yes. Up to 3 extra user-selectable visible light image capture to be included in IS2 file. |
| Text annotations | After IS2 capture, user can type in a note using on-screen keyboard. |
| Video recording and formats | Standard and radiometric video. Up to 5 minute recording length. avi and is3 |
| Remote control operations | No |
| Auto capture (temperature and interval) | Yes. User-selectable time interval for capturing IS2 or Jpeg files. |
| Batteries (field-replaceable, rechargeable) | Lithium-ion rechargeable battery |
| Battery life | ≥3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
| Battery charging time | ≤2.5 hours to full charge |
| Battery charging system | Ti SBC3B Two-Bay Battery Charger or in-Imager charging. |
| AC operation | AC operation with included power supply, universal adapters included Output: 15 VDC, 2 A |
| Power saving | User-selectable sleep and power off |
| Temperature range (not calibrated below -10 °C) | -20 °C to 550°C (not calibrated below -10 °C) |
| On-screen emissivity correction | Yes, “top ten” material list plus numerical adjustment between 0.01 and 1.00 |
| Standard palettes | 6 |
| Color alarms | Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature. |
| Infrared spectral band | ~8-14μm |
| Operating temperature | -10 °C to 50 °C (14 °F to 122 °F) |
| Storage temperature | -20 °C to 50 °C (-4 °F to 122 °F) without batteries |
| Relative humidity | 10 % to 95 % non-condensing |
| Spot temperature | Center spot (unmovable) |
| User-definable spot markers | Yes, 5 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker. |
| User defined measurement boxes | Yes, 5 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker. |
| Hard case | Rugged hard carrying case with soft transport bag, including adjustable strap |
| Safety standards | IEC 61010-1: Pollution Degree 2 |
| Electromagnetic combability | IEC 61326-1: Portable Electromagnetic Environment;IEC 61326-2-2 CISPR 11: Group 1, Class A |
| Australian RCM | RCM IEC 61326-1 |
| US FCC | 47 CFR 15 Subpart C Sections 15.207, 15.209, 15.249 |
| Vibration | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 |
| Shock | 30 g, 11 ms, IEC 60068-2-27 |
| Drop | Engineered to withstand 2m drop |
| Sized (H x W x L) | ∼(26.7 cm x 10.1 cm x 14.5 cm)∼ (10.5 in x 4.0 in x 5.7 in) |
| Weight (battery included) | 0.885 kg (1.95 lbs) |
| Enclosure rating | IP54 |
| Warranty | Two-years (standard) |
| Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
| Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
| RoHS compliant | Yes |
This product is part of a family with 4 models. Select a model below to view details.
| Model | Price | |
|---|---|---|
FLUKE-PVA-1500/FPC | Request Quote | View Details → |
FLUKE-PVA-1500/FPC3 | Request Quote | View Details → |
FLUKE-PVA-1500HE2 | Request Quote | View Details → |
FLUKE-PVA-1500T2Current | Request Quote | Viewing |

Fluke TLPV1 MC4 to 4mm Test Lead Set ensures safe PV measurements with Staubli MC4 connectors, CAT III 1500V. Ideal for maintenance and troubleshooting.
Fluke 393 FC Clamp, IRR1 Irradiance Meter, MC4 TL Bundle

393 FC solar clamp meter measures up to 1500 V dc, 1000 V ac, IP54 rated, CAT III. Ideal for PV installation, solar PV arrays, electric railways and data centers.

The Fluke FLK-IRR1-SOL Solar Irradiance Kit comes with a meter, temperature probe and soft carrying case.