The Fluke ii915 Acoustic Imager provides easy, fast, and safe detection and assessment of compressed gas leaks, partial discharges, and mechanical anomalies.
The Fluke ii915 Acoustic Imager # FLUKE-II915 is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| Frequency band | 2 kHz to 100 kHz2 kHz to 52 kHz |
| Detection range1 | 0.5 to > 120 meters(1.6 to > 393 feet) |
| Field of view (FOV) | 63°± 5° |
| Nominal frame rate | 25 FPS |
| Focus | Fixed lens |
| Zoom | 3 x digital zoom |
| Resolution | 5 MP |
| Size | 7" LCD with backlight, sunlight readable |
| Touchscreen | Capacitive |
| Acoustic image | SoundMapTM image |
| Storage capacity | 32 GB(> 8,000 pictures / > 1,600 videos) |
| Image format | Blended visual and SoundMapTM .JPG or .PNG |
| Video format | Blended visual and SoundMapTM .MP4 |
| Video length | Up to 5 minutes |
| Digital export | USB-C for data transfer |
| Measurement range (typical) | 12.1 to 114.6 dB SPL(± 1 dB SPL 2 kHz)4.4 to 101.2 dB SPL(± 2 dB SPL 19 kHz)12.8 to 119.2 dB SPL(± 1 dB SPL 35 kHz)19.8 to 116.1 dB SPL(± 3 dB SPL 52 kHz)41.4 to 129.0 dB SPL(± 1 dB SPL 80 kHz)54.4 to 135.5 dB SPL(± 1 dB SPL 100 kHz) |
| LeakQTM | Leak size scale, Leak rate, and Leak cost estimation |
| PDQ ModeTM | Partial discharge type classification |
| MecQTM | Mechanical anomaly detection |
| Auto max/min dB gain | Auto or manual, user selectable |
| Frequency band selection | User selectable through user-made presets or manual entry |
| Battery | Rechargeable and field replaceable Li-ion battery |
| Battery life | 6 hours |
| Battery charging time | ~3,5 hours |
| Battery charging system | Internal (USB-C) |
| Ease of use | Intuitive user interface |
| Acoustics: Show dB scale | On/Off |
| Acoustics: Min/Max dB | Manual/Auto |
| Acoustics: Profiles | Preset capture profiles |
| Acoustics: High frequency | Yes |
| Acoustics: Multiple sources | Show single or multiple sources |
| Palette: Colors | 3: Grayscale, Ironbow, and Blue-Red |
| Palette: Overly transparency | Yes: 1-100% |
| Grayscale mode | Yes |
| Centerpoint markers | On/Off |
| Trend graphs | Frequency and dB scale |
| Spotmarkers | dB level reading at center point of image |
| Leak values | Leak costs, Leak volume, LeakQTM scale (1-10)2 |
| Master admin menu | Yes |
| Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure |
| Photo notes | Up to 4 photos notes for reference |
| Asset inspection status | 'As left', 'As found', 'Undetermined' |
| Asset ID | Text input and automatic QR code based asset ID identification |
| Actions annotation | Action requirements, Action priority level, Action notes |
| Other | Operating conditions, Weather notes |
| Tripod holder / connector | Yes: 1/4"-20 |
| USB | 2 x USB-C |
| Wireless | Wifi |
| Operating Temperature | -10 to 45 °C (14 to 113 °F) |
| Storage Temperature | -20 to 70 °C (-4 to 158 °F) without batteries installed |
| Relative humidity | 10 to 95 % non-condensing |
| Size (H x W x L) | 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) |
| Weight (battery included) | 2 kg (4.4 pounds) |
| Ingress Protection (IP) | IP40 |
| Warranty | 2 year |
| Fluke Premium Care | Premium Care Standard3 |
| Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
| Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
| RoHS compliant | Yes |
| General safety | IEC 61010-1 |
| Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A |
| Korea (KCC) | Class A Equipment (Industrial Broadcasting and Communication) |
| USA (FCC) | 47 CFR 15 sub part B. This product is considered an exempt device per clause 15.103 |
This product is part of a family with 2 models. Select a model below to view details.
| Model | Price | |
|---|---|---|
FLUKE-II915Current | Request Quote | Viewing |
FLUKE-II915/SB140 | Request Quote | View Details → |
Upgrade leak detection for non-pressurized vessels with the Fluke SB140 SoundBeacon ultrasonic transmitter. Compatible with Fluke ii905 and ii915 Acoustic Imagers.

Quickly detects and locates gas leaks with advanced sound visualization, an intuitive interface, and a ready-to-use design.

Detect, locate, and assess gas and vacuum leaks in compressed air systems, pipelines, and industrial equipment.

087724767001 TS30/120 Angl/Pin