SKU: FLK-A3002FC
AC/DC Current Module That Wirelessly Relays Measurements from Current Clamp Accessories to Other Fluke Connect Enabled Master Units
List price. Volume pricing available.
AC/DC current module that wirelessly relays measurements from current clamp accessories to other Fluke Connect enabled master units
The Fluke a3002FC Wireless AC/DC Current Module FC # FLK-A3002FC is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| General | AC/DC Current Function |
| Range / resolution | 1000 A / 0.1 A |
| Accuracy1 | (0.5% + 3) |
| A AC | 1. AC accuracy is specified from 45 Hz to 1000 Hz |
| Maximum voltage between terminal and earth ground (module) | 30 V DC or AC RMS |
| LCD w/backlight | 3½ digits, 6000 counts, 4/sec update rate |
| Log rate/Interval | Adjustable by PC from 1 sec to 1 hr, default 1 min |
| Battery type | 2 AA Alkaline batteries, NEDA 15A, IEC LR6 |
| Battery life | 400 hours minimum |
| Memory | Record up to 65,000 readings |
| RF communications | 2.4 GHz ISM Band |
| Open air, unobstructed | Up to 20 m |
| Obstructed, sheetrock wall | Up to 6.5 m |
| Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m |
| Operating temperature | -10°C to +50°C |
| Storage temperature | -40°C to +60°C |
| Temperature coefficient | 0.1 X (specified accuracy) / °C ( 28°C) |
| Relative humidity | 0% to 90% (0°C to 35°C)0% to 75% (35°C to 40°C)0% to 45% (40°C to 50°C) |
| EMC | IEC 61236-1, Portable |
| Safety compliance | Protected to IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition Pollution Degree 2 |
| Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
| Ingress Protection (IP) rating | IP42 |
| Size (HxWxD) | 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in) |
| Weight | 0.255 kg (9 oz) |
| Warranty | Three years |
| RF communication range | Not compatible with Fluke CNX test tools |

Get the right HVAC multimeter for accurate temperature & microamp measurements. The Fluke 116 digital multimeter has everything you need in an HVAC meter.

The Fluke i40s-EL Current Clamp-on Transformer is used for low current measurement; suitable for making measurements up to 40A, and also measures accurately on 1A and 5A secondary current transformers.

The 80I-110s is compatible with any Fluke ScopeMeter Test Tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage measurement device that has the following features: BNC input connectors or if using a meter convert the banana plugs to a BNC connector using the adapter PM9081/001.

The slim and thin jaw can easily fit into tightly packed wires. The lightweight and compact design allows you to carry it around in your pocket