SKU: FLUKE-725 US
Fluke 725 handheld multifunction process calibrator. Sources and measures pressure (via any of 29 Fluke 700-series pressure modules), thermocouples, RTDs, mA, volts, ohms, and frequency — the single tool most process techs need to calibrate almost any process instrument. Dual display, mA source with 25 % step and automatic ramp, loop-power output, and switch-test mode make transmitter and switch calibration straightforward. Targeted at process plants, refineries, and pharmaceutical or food & beverage facilities where one technician covers a wide mix of instrumentation.
List price. Volume pricing available.
Fluke 725 Multifunction Process Calibrator calibrates almost anything & sources & measures almost all process parameters. Versatile, powerful.
The Fluke 725 US Multifunction Process Calibrator # FLUKE-725 US is manufactured by Fluke. Valley Instrument Service is an authorized Fluke dealer offering full sales support, NIST-traceable calibration, and expert technical assistance.
Our team can help with product selection, specs, pricing, and application support.
Contact Us or Call (661) 327-8681| General | Measurement Accuracy |
| 30.000 V | 0.02% + 2 counts (upper display) |
| 100.00 mV | 0.02% + 2 counts |
| -10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) |
| Current DC | 24.000 mA |
| 0.0 to 400.0 Ω | 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
| 401 to 1500 Ω | 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) |
| 1500 to 3200 Ω | 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
| 2.0 to 1000.0 CPM | 0.05% + 1 count |
| 1.0 to 1100.0 Hz | 0.05% + 1 count |
| 1.00 to 10.00 kHz | 0.05% + 1 count |
| Sensitivity | 1 V peak-to-peak-minimum |
| Pressure | Accuracy from 0.025% of range using any of (50) 750P pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
| Frequency | Source Accuracy |
| 10.000 V | 0.02% + 2 counts |
| 24.000 mA (source) | 0.02% + 2 counts |
| 24.000 mA (simulate) | 0.02% + 2 counts |
| 15.0 to 400.0 Ω | 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
| Waveform | 5 V p-p squarewave, -0.1 V offset |
| NI-120 | 0.2°C |
| PT-100 (385) | 0.33°C |
| PT-100 (393) | 0.3°C |
| PT-100 (JIS) | 0.3°C |
| PT-200 (385) | 0.2°C |
| PT-500 (385) | 0.3°C |
| PT-1000 (385) | 0.2°C |
| Resolution | 0.1°C |
| J | 0.7°C |
| K | 0.8°C |
| T | 0.8°C |
| E | 0.7°C |
| R | 1.8°C |
| S | 1.5°C |
| B | 1.4°C |
| L | 0.7°C |
| U | 0.75°C |
| N | 0.9°C |
| XK | 0.6°C |
| BP | 1.2°C |
| Source accuracy | Accuracy stated for 4-wire measurement. |
| Source functions | Voltage, current, resistance, frequency, temperature |
| Ramps | Slow ramp, Fast ramp, 25% step-ramp |
| Voltage | 24 V |
| Accuracy | 10% |
| Maximum current | 22 mA, short circuit protected |
| Steps | 25% of range, 100% of range |
| Step functions | Environmental Specifications |
| Operating temperature | -10°C to +55°C |
| Storage temperature | -20°C to 71°C |
| Operating altitude | 3000 m |
| Agency approvals | EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992 |
| Size | 130 x 236 x 61 mm |
| Weight | 0.65 kg |
| Batteries | 4 AA alkaline batteries |
| Battery replacement | Separate battery compartment, accessable without breaking calibration seal |
| Side port connections | Pressure module connector, also used for remote real-time programming |

The Fluke 154 HART Communicator is a standalone tablet based tool that wirelessly connects to the HART transmitter. See the specs or talk with an engineer.

Very accurate current shunt to use for verification and calibration of process control loops.
Process Calibration Deluxe Test Lead Kit

Fluke Calibration 71XTrap Liquid-Dirt Trap Shields 718, 719 & 729 Pressure Calibrators from Moisture; Protects the Pump and Hose from Contamination